Overview
Over the past decade, the tight and transparent sound of
Lab.gruppen touring amplifiers has earned the praise of renowned FOH engineers
and leading sound rental companies worldwide. FP 14000, the new flagship model
of the FP+ Series, advances this tradition by further augmenting effective
power output to effortlessly handle extreme low-frequency loads.The Regulated
Switch Mode Power Supply (R.SMPS) has been updated to provide more sustained
high power during extended bursts of low frequency content, while at the same
time ensuring stable rail voltages even with wide fluctuations of external
mains voltage.
- The forceful, high-current (83 A peak) output stage relies on
Lab.gruppen’s patented Class TD topology, a breakthrough in amplifier
technology that approaches the efficiency of Class D while retaining the sonic
purity of proven Class B designs. A highly refined and efficient circuit layout
further optimizes the interaction of R.SMPS and Class TD to produce the
unprecedented power density of the FP 14000.
- To keep its cool under extreme demands, the FP 14000 relies
on Lab.gruppen’s proprietary Intercooler. This innovation uses thousands of
copper fins to multiply the exposed heatsink surface’s rapid heat dissipation.
Also, all output devices are mounted transverse to the airflow for uniform
cooling. As a result, the FP 14000 delivers Lab.gruppen’s’ trademark “all the
power, all the time” with no degradation of sonic performance.
- To maximize headroom in any application, the FP 14000 offers
adjustable input gain along with Lab.gruppen’s exclusive Voltage Peak Limiter
(VPL). Adjustable on a per-channel basis, VPL optimizes the output for any
load, from a single massive subwoofer to a series of HF compression drivers.
- The comprehensive warning and protection features on the FP
14000 safeguard output circuits and connected loads while also extending
amplifier life and minimizing the chance of service interuptions Whether it’s a
matter of faulty wiring, improper use, or extreme ambient temperatures, the FP
14000 gives clear indication of any problems. Automatic protection measures
engage only at critical thresholds. Operating conditions are re-checked every
six seconds and, if a fault is detected, normal operation is resumed when
measurements return to nominal.
- The FP 14000 is shipped with a NomadLink network interface
as standard. In conjunction with DeviceControl software, NomadLink allows
comprehensive monitoring of amplifier status (including fault or warning
indications) and also enables remote control of power on/off, channel mute, and
channel solo functions. NomadLink is compatible with popular third-party
control platforms; a separate NLB 60E NomadLink Bridge & Network Controller
is required.
Features:
- Unprecedented power density – The FP 14000 delivers a total
of 14000 W (2 x 7000 W @ 2 ohms) in only 2U.
- Lab.gruppen sound quality – The FP 14000 is optimized for
sustained performance into extreme low-frequency loads, yet it also maintains
Lab.gruppen’s reputation for exceptionally smooth and transparent mid- and high-frequency
response.
- NomadLink® network ready – Monitoring and control of key
functions accessible via the intuitive DeviceControl software and the robust,
daisy-chained NomadLink® network, as well as by the leading third party control
platforms.
- Patented Class TD® amplifier topology – Road-proven output
stage delivers Class B audio quality with Class D efficiency.
- Regulated Switch Mode Power Supply (R.SMPS™) – Output power
remains constant even with significant drops in the mains voltage.
- Efficient cooling system – Unique, lightweight Intercooler
copper cooling system dissipates more heat to allow extended peak output
- Adjustable parameters – Selectable Gain, scalable Voltage
Peak Limiter (VPL™), and bridge-mode operation allow custom configuration for
any system or application.
- XLR input and link connectors
- Heavy-duty binding posts
- Comprehensive protection and warning – Excessive output
current, DC, high temperature, very high frequency (VHF), short circuit, open
load, mains fuse protection, and soft start.
Panel Features:
Specifications:
General
- Number of channels ............................................. 2
- Peak total output all channels driven .............14000 W
- Peak output voltage per channel ...................... 195 V
- Max output current per channel............................. 90 A peak
Max output power all channels driven
- 16 ohms.................... 1200
W
- 8 ohms .......................2350 W
- 4 ohms........................ 4600 W
- 2 ohms........................... 7000 W
Max output power bridged
- 16 ohms .......................4700
W
- 8 ohms.............................. 8800 W
- 4 ohms ..........................14000 W
- 2 ohms .......................The amplifier
will be fully operational at bridge-mode 2 ohm loads, but due to physical
constraints in the construction, the max. output power will not be
significantly higher than running individual channels and therefore not stated
here.
Performance
- THD 20 Hz - 20 kHz at 1W......................................... <0.1%
- THD at 1 kHz and 1 dB below clipping....................<0.05%
- Signal to Noise Ratio.................................................>112
dBA
- Channel separation (Crosstalk) at 1 kHz ..................>70 dB
- Input impedance .........................................................20
kOhm
- Output impedance @ 100 Hz ..................................19
mOhm
Gain, Sensitivity and Limiters
- VPL, selectable per ch...............................195,
170, 140, 116, 100, 80, 66, 54 V
- VPL, when bridged ....................................... 390,
340, 280, 232, 200, 160, 132, 108 V
- Voltage Peak Limiter mode (per ch.) ..........Hard / Soft
- Amplifier gain selectable (all channels) – rear-panel
switches ........... 23, 26, 29, 32, 35, 38, 41,
44 dB
- Default gain...................................................... 38
dB
- Level adjustment (per channel)......................... Front-panel potentiometer, 31 position detented from
-inf to
Connectors and Buttons
- Input connectors (per ch.) ........................... 3-pin
XLR, electronically balanced
- Output connectors (per ch.)..........................Neutrik
speakON / binding post
- Output bridge mode ....................................... A+B
- Ch. A is signal input source. A+B, C+D - Ch.’s A and C are input source
- NomadLink network......................................On
board, 2 x RJ45 connectors IN and OUT
- Intelligent fans (on/off).............................................. Yes,
depending on presence of output signal
- Power on/off and Remote enable on/off .................... Individual switches on front-panel
- Cooling ......................................Dual fan, front
to rear airflow, no filter required, temperature controlled speed
Front-panel user interface
- Common.............................. NomadLink
Network; Power Average Limiter (PAL)5; Power on
- Per channel...........................Signal
present / High-impedance; -10 dB and -4 dB output signal;Voltage Peak Limiter
(VPL); Current Peak Limiter (CPL): Very High Frequency (VHF); High temperature;
Fault; Mute
Power
- Operating voltage, 230 V / 115 V nominal ............................130-265 V / 65 -135 V
- Minimum power-up voltage, 230 V / 115 V ............................171 V / 85 V
- 3 ...................................................................................................... Yes
- Soft-start / Inrush Current Draw ......................... Yes / max. 5 A
- Mains connector......................................... 230
V CE: 16 A, CEE7; 115 V ETL: 30 A Twist lock
Dimensions
- Dimensions.............................W:
483 mm (19”), H: 88 mm (2 U), D: 396 mm (15.6”)
Weight
- Weight............................. 12 kg (26.4 lbs)
Finish
- Finish ............................Black painted
steel chassis with black painted steel / aluminum front
Approvals
- Approvals.....................CE,
ANSI/UL 60065 (ETL), CSA C22.2 NO. 60065, FCC
NOTES
1: Automatic -6 dB gain compensation when bridging channels.
2: Separate 230 V or 115 V versions available. Not
selectable on the amplifier.
3: PAL can reduce the maximum output power to keep the power
supply operating safely, and/or to prevent excessive current draw tripping the
mains breaker. Refer to the FP+ Operation Manual section 7.5.8 Power Average
Limiter (PAL) for more information.