Overview:
Occupying the middle of the FP+ Series in power ratings for
two-channel models, the FP 9000 provides versatility and value across a wide
range of applications for full-range cabinets, band-limited line array systems,
and stage monitoring. A refined Class TD® output stage is optimized for
effortless reproduction of extreme low frequency content, while the Regulated
Switch Mode Power Supply (R.SMPS) has been updated to provide more sustained
high power during extended bursts of low frequency content.
Network control
- The FP 9000 is shipped with a NomadLink® network interface
as standard. In conjunction with DeviceControl software, NomadLink allows
monitoring of all key amplifier parameters and remote control of power on/off,
channel mutes, and channel solo functions.
- NB. NomadLink requires the separate NLB 60E NomadLink Bridge
& Network Controller
Proven ergonomics
- View all key performance parameters at a glance – in real
time – on the comprehensive front panel display. The FP+ provides the most
complete and useful front panel indication on the market today. Bright,
color-coded LEDs give clear status indication of all control activation,
warnings and faults – without scrolling through menus. Conditions such as blown
drivers, shorted lines, and over-temperature channels are easily recognizable.
You won’t waste time trying to decipher a generic “trouble light.”
Around the back
- The FP+ rear panel provides all the input and output
connections you’ll need plus RJ45 in and out for NomadLink® control and
monitoring. With the DIP-switch matrix, you can assign a hard or soft attack to
the limiter functions, set overall gain to one of seven different levels,
bridge any pair of channels, and set the VPL for optimum output characteristics
with the connected load. All in a matter of seconds while the amp is in the
rack.
Under the hood
- To achieve the extreme power-to-size ratio in the FP+
Series, Lab.gruppen engineers refined and upgraded two proprietary
technologies: the regulated switch-mode power supply (R.SMPS™) and the patented
Class TD™ output stage. Both are incorporated in all four FP+ Series
amplifiers. Working together, this new generation of proprietary circuits
produces more power from a smaller package while at the same time maintaining
Lab.gruppen’s peerless reputation for sonic excellence.
- To ensure efficient, uniform cooling, the ultra-efficient
Intercooler® uses thousands of tiny cooper cooling fins to increase exposure of
the heat sink to the cooling air flow. Twin variable-speed fans respond to
temperature sensors, forcing air over the Intercooler fins in a front-to-rear
flow. All output devices are mounted transverse to the airflow, so the cooling
effect is uniform. There are no “end-of-tunnel” output transistors subject to
greater warming and, consequently, possible premature failure.
Features:
- Exceptional power density – The FP 9000 delivers a total of
9000 W (2 x 4500 W @ 2 ohms) in only 2U.
- Lab.gruppen sound quality – impeccable sonic performance
standards with durability and greater efficiency
- NomadLink® network ready – Monitoring and control of key
functions accessible via the intuitive DeviceControl software
- Patented Class TD amplifier topology – Road-proven output
stage delivers Class B audio quality with Class D efficiency
- Regulated Switch Mode Power Supply (R.SMPS) – Output power
remains constant even with significant drops in the mains voltage
- Efficient cooling system - Unique, lightweight Intercoller
copper cooling system dissipates more heat to allow extended peak output
- Adjustable parameters - Selectable Gain, scalable Voltage
Peak Limiter (VPL), and bridge-mode operation allow custom configuration for
any application
- Comprehensive protection and warning – Excessive output
current, DC, high temperature, very high frequency (VHF), short circuit, open
load, mains fuse protection, and soft start
- XLR input connectors
- Heavy-duty binding post or Speakon output connectors
Panel Features:
Specifications:
General
- Number of channels.................................2
- Peak total output all channels driven ..........9000 W
- Peak output voltage per channel ................170 V
- Max output current per channel ....................70 A peak
Max output power all channels driven
- 16 ohms ...........................800
W
- 8 ohms............................1600 W
- 4 ohms............................3000 W
- 2 ohms............................4500 W
Max output power bridged
- 16 ohms........................3200
W
- 8 ohms.........................6000 W
- 4 ohms...............................9000 W
- 2 ohms.........................The amplifier
will be fully operational at bridge-mode 2 ohm loads, but due to physical constraints
in the construction, the max. output power will not be significantly higher
than running individual channels and therefore not stated here.
Performance
- THD 20 Hz - 20 kHz at 1W................................<0.1%
- THD at 1 kHz and 1 dB below clipping................<0.05%
- Signal to Noise Ratio........................................>112
dBA
- Channel separation (Crosstalk) at 1 kHz.............. >70 dB
- Input impedance...............................................20
kOhm
- Output impedance @ 100 Hz...........................19
mOhm
Gain, Sensitivity and Limiters
- VPL, selectable per ch .............170,
140, 116, 100, 80, 66, 54 V
- VPL, when bridged.....................340,
280, 232, 200, 160, 132, 108 V
- Voltage Peak Limiter mode (per ch.).............. Hard / Soft
- Amplifier gain selectable (all channels) – rear-panel
switches..................23, 26, 29, 32, 35, 38, 41,
44 dB
- Default gain ......................................38
dB
- Level adjustment (per channel) .............. Front-panel potentiometer, 31 position detented from -inf
to
Connectors and Buttons
- Input connectors (per ch.) ...................3-pin
XLR, electronically balanced
- Output connectors (per ch.) ......................Neutrik
speakON / binding post
- Output bridge mode...........................A+B
- Ch. A is signal input source. A+B, C+D - Ch.’s A and C are input source
- NomadLink network..........................On
board, 2 x RJ45 connectors IN and OUT
- Intelligent fans (on/off) ...............................Yes,
depending on presence of output signal
- Power on/off and Remote enable on/off ...................... Individual switches on front-panel
- Cooling .....................................Dual fan, front
to rear airflow, no filter required, temperature controlled speed
Front-panel user interface
- Common........................NomadLink
Network; Power Average Limiter (PAL)5; Power on
- Per channel...................... Signal
present / High-impedance; -10 dB and -4 dB output signal;Voltage Peak Limiter
(VPL); Current Peak Limiter (CPL): Very High Frequency (VHF); High temperature;
Fault; Mute
Power
- Operating voltage, 230 V / 115 V nominal .............130-265 V / 65 -135 V
- Minimum power-up voltage, 230 V / 115 V..................171 V / 85 V
- 3 .......................................................Yes
- Soft-start / Inrush Current Draw...................Yes / max. 5 A
- Mains connector.......................... 230
V CE: 16 A, CEE7; 115 V ETL: 30 A Twist lock
Dimensions
- Dimensions....................W:
483 mm (19”), H: 88 mm (2 U), D: 396 mm (15.6”)
Weight
- Weight.....................12 kg (26.4 lbs)
Finish
- Finish....................Black painted
steel chassis with black painted steel / aluminum front
Approvals
- Approvals....................CE,
ANSI/UL 60065 (ETL), CSA C22.2 NO. 60065, FCC
NOTES
1: Automatic -6 dB gain compensation when bridging channels.
2: Separate 230 V or 115 V versions available. Not
selectable on the amplifier.
3: PAL can reduce the maximum output power to keep the power
supply operating safely, and/or to prevent excessive current draw tripping the
mains breaker. Refer to the FP+ Operation Manual section 7.5.8 Power Average
Limiter (PAL) for more information.