The LAB GRUPPEN FP 10000Qis the flagship four-channel model in the FP+
Series. At the core of the FP 10000Q’s performance is the now proven
technological milestone that is Lab.gruppen’s patented Class TD® output stage,
an amplifier topology that approaches the exceptional efficiency of Class D
while retaining the sonic purity of proven Class B designs. Further
contributing to the remarkable efficiency of the FP 10000Q is a Regulated
Switch Mode Power Supply (R.SMPS™), which gives the added benefit of
stabilizing rail voltages to the output even with wide fluctuations of mains
voltage. A highly refined and updated circuit layout optimizes the interaction
of R.SMPS and Class TD to produce the extraordinary power density of the FP
10000Q.
Network control
The FP 10000Q is shipped with a NomadLink® network interface
as standard. In conjunction with DeviceControl PC software, NomadLink allows
monitoring of all key amplifier parameters and remote control of power on/off,
channel mutes, and channel solo functions.
NB. operation of NomadLink requires the NLB 60E NomadLink
Bridge & Network Controller which must be purchased separately.
Proven ergonomics
View all key performance parameters at a glance – in real
time – on the comprehensive front panel display. The FP+ provides the most
complete and useful front panel indication on the market today. Bright,
color-coded LEDs give clear status indication of all control activation,
warnings and faults – without scrolling through menus. Conditions such as blown
drivers, shorted lines, and over-temperature channels are easily recognizable.
You won’t waste time trying to decipher a generic “trouble light.”
Around the back
The FP+ rear panel provides all the input and output
connections you’ll need plus RJ45 in and out for NomadLink® control and
monitoring. With the DIP-switch matrix, you can assign a hard or soft attack to
the limiter functions, set overall gain to one of seven different levels,
bridge any pair of channels, and set the VPL for optimum output characteristics
with the connected load. All in a matter of seconds while the amp is in the
rack.
Under the hood
To achieve the extreme power-to-size ratio in the FP+
Series, Lab.gruppen engineers refined and upgraded two proprietary
technologies: the regulated switch-mode power supply (R.SMPS™) and the patented
Class TD™ output stage. Both are incorporated in all four FP+ Series
amplifiers. Working together, this new generation of proprietary circuits
produces more power from a smaller package while at the same time maintaining
Lab.gruppen’s peerless reputation for sonic excellence.
To ensure efficient, uniform cooling, the ultra-efficient
Intercooler® uses thousands of tiny cooper cooling fins to increase exposure of
the heat sink to the cooling air flow. Twin variable-speed fans respond to
temperature sensors, forcing air over the Intercooler fins in a front-to-rear
flow. All output devices are mounted transverse to the airflow, so the cooling
effect is uniform. There are no “end-of-tunnel” output transistors subject to
greater warming and, consequently, possible premature failure.
Features:
Very high power and channel density – The four-channel
FP10000Q delivers a total of 10000 W (4 x 2500 W @ 2 ohms) in only 2U
Four-channel flexibility – Adjacent channels bridgeable for
2- or 3-channel operation
Lab.gruppen sound quality – impeccable sonic performance
standards with durability and greater efficiency
NomadLink® network ready – Monitoring and control of key
functions accessible via the intuitive DeviceControl software
Patented Class TD amplifier topology – Road-proven output
stage delivers Class B audio quality with Class D efficiency
Regulated Switch Mode Power Supply (R.SMPS) – Output power
remains constant even with significant drops in the mains voltage
Efficient cooling system - Unique, lightweight Intercoller
copper cooling system dissipates more heat to allow extended peak output
Adjustable parameters - Selectable Gain, scalable Voltage
Peak Limiter (VPL), and bridge-mode operation allow custom configuration for
any application
Comprehensive protection and warning – Excessive output
current, DC, high temperature, very high frequency (VHF), short circuit, open
load, mains fuse protection, and soft start
XLR input connectors
Heavy-duty binding post or Speakon output connectors
Panel Features:
Specifications:
General
Number of channels...................................4
Peak total output all channels driven.............10000 W
Peak output voltage per channel...................150 V
Max output current per channel....................50 A peak
Max output power all channels driven
16 ohms...................660
W
8 ohms ...................1300 W
4 ohms....................2100 W
2 ohms....................2500 W
Max output power bridged
16 ohms........................2600
W
8 ohms........................4200 W
4 ohms...............................5000 W
2 ohms.............The amplifier
will be fully operational at bridge-mode 2 ohm loads, but due to physical constraints
in the construction, the max. output power will not be significantly higher
than running individual channels and therefore not stated here.
Performance
THD 20 Hz - 20 kHz at 1W...........................<0.1%
THD at 1 kHz and 1 dB below clipping.........<0.05%
Signal to Noise Ratio.................................>112
dBA
Channel separation (Crosstalk) at 1 kHz.......>70 dB
Output bridge mode ........................ A+B
- Ch. A is signal input source. A+B, C+D - Ch.’s A and C are input source
NomadLink network...........................On
board, 2 x RJ45 connectors IN and OUT
Intelligent fans (on/off) ...............................Yes,
depending on presence of output signal
Power on/off and Remote enable on/off ................... Individual switches on front-panel
Cooling..............................Dual fan, front
to rear airflow, no filter required, temperature controlled speed
Front-panel user interface
Common.....................NomadLink
Network; Power Average Limiter (PAL)5; Power on
Per channel.................Signal
present / High-impedance; -10 dB and -4 dB output signal;Voltage Peak Limiter
(VPL); Current Peak Limiter (CPL): Very High Frequency (VHF); High temperature;
Fault; Mute
Power
Operating voltage, 230 V / 115 V nominal ................ 130-265 V / 65 -135 V
Minimum power-up voltage, 230 V / 115 V ..................171 V / 85 V
1: Automatic -6 dB gain compensation when bridging channels.
2: Separate 230 V or 115 V versions available. Not
selectable on the amplifier.
3: PAL can reduce the maximum output power to keep the power
supply operating safely, and/or to prevent excessive current draw tripping the
mains breaker. Refer to the FP+ Operation Manual section 7.5.8 Power Average
Limiter (PAL) for more information.